PARAMETERS

4.2.38 V/F control frequency (voltage) (Pr. 100 to Pr. 109)

Pr. 100 "V/F1 (first frequency)"

Pr. 101 "V/F1 (first frequency voltage)" Pr. 102 "V/F2 (second frequency)"

Pr. 103 "V/F2 (second frequency voltage)" Pr. 104 "V/F3 (third frequency)"

Pr. 105 "V/F3 (third frequency voltage)" Pr. 106 "V/F4 (fourth frequency)"

Pr. 107 "V/F4 (fourth frequency voltage)" Pr. 108 "V/F5 (fifth frequency)"

Pr. 109 "V/F5 (fifth frequency voltage)"

Related parameters

Pr. 19 "base frequency voltage"

Pr. 47 "second V/F (base frequency)" Pr. 60 "intelligent mode selection" Pr. 71 "applied motor"

You can make a dedicated V/F pattern by using V/F (frequency Voltage/Frequency) control to set V/F characteristics from the start to the basic frequency and basic voltage as desired.

#Desired V/F characteristics can be set by presetting V/F1 (first frequency voltage/first frequency), V/F2, V/F3, V/F4 and V/F5 in the corresponding parameters.

Parameter

Factory

Setting Range

Remarks

Number

Setting

 

 

100

9999

0 to 120Hz, 9999

 

101

0

0 to 1000V

 

102

9999

0 to 120Hz, 9999

 

103

0

0 to 1000V

Set "2" in Pr. 71 and a value

104

9999

0 to 120Hz, 9999

other than 9999 in Pr. 19.

105

0

0 to 1000V

These functions are active

106

9999

0 to 120Hz, 9999

only when Pr. 60 = 0.

107

0

0 to 1000V

 

108

9999

0 to 120Hz, 9999

 

109

0

0 to 1000V

 

Voltage

Base frequency voltage

(Pr. 19)

Boost value

(Pr. 0)

 

V/F4

 

V/F5

V/F1

V/F3

 

 

V/F2

 

Frequency

0Base frequency

V/F characteristic

(Pr. 3)

 

<Setting>

(1) Confirm the settings of Pr. 19, Pr. 60 and Pr. 71.

Parameter Number

Description

19Set the rated motor voltage.

This function is not activated if its value is "9999" and "8888" (factory setting).

60

Set "0"

(ordinary operation mode).

71

Set "2"

(V/F 5-point flexible characteristic).

108

Page 121
Image 121
Mitsumi electronic FR-F520-0.75K, 55K 38 V/F control frequency voltage Pr to Pr, Confirm the settings of Pr , Pr and Pr