Table3-31 Console/Telnet Settings
Field Description
Baud Rate Enter a rate from 110 to 115,200, expressed
in bits per second.
The rate you enter is dependent on the
capability of the computer you use to open
the access point management system.
Parity From the list, select one of the following:
NoneUse this setting to use no parity
bit.
EvenUse this setting to make the total
number of bits even.
OddUse this setting to make the total
number of bits odd.
Data Bits From the list, select one of the data bit
settings.
Stop Bits From the list, select one of the stop bit
settings.
Flow Control From the list, select one of the following:
NoneUse this setting to indicate no
flow control is used.
SW Xonn/XoffUse this setting to
indicate the method information is sent
between pieces of equipment to prevent
loss of data when too much information
arrives at the same time on one device.
Terminal Type From the list, select one of the following:
teletypeUse this setting if your
terminal emulator does not support
ANSI.
ANSIUse this setting to offer graphic
features such as reverse video buttons
and underlined links.