DMA Operations Guide

Local Cluster Configuration Procedures

 

 

Local Cluster Configuration Procedures

This section describes the following Polycom DMA 7000 system configuration procedures:

Add Licenses

Configure Signaling

Configure Logging

If you’re performing the initial configuration of your Polycom DMA system, study “Polycom® DMASystem Initial Configuration Summary” on page 23 before you continue. Other tasks are required that are described elsewhere.

Add Licenses

Adding licenses to your Polycom DMA system is a two-step process:

Request a software activation key code for each server.

Enter the activation key codes into the system.

The procedures below describe the process.

To request a software activation key code for each server

1Log into the Polycom DMA system as an administrator and go to Admin > Local Cluster > Licenses.

2Record the serial number for each Polycom DMA server:

Server A: ____________________________

Server B: ____________________________ (none for single-server system)

3Go to http://www.polycom.com/activation.

4If you don’t already have one, register for an account. Then log in.

5 Select Product Activation.

6In the License Number field, enter the software license number listed on the first (or only) server’s License Certificate (shipped with the product).

7In the Serial Number field, enter the first (or only) server’s serial number (which you recorded in step 2).

8Click Generate.

9When the activation key for the first (or only) server appears, record it: Server A: __________-__________-_________-___________

10If you have a single-server Polycom DMA system, you’re finished with this procedure. Continue to the next procedure.