Login Policy Settings

System Security

 

 

Table 3-7

Fields on the Session Settings page

 

 

 

Field

 

Description

 

 

Active system sessions

Specify the number of simultaneous login sessions by

 

 

all users or select Unlimited.

 

 

Note: If this limit is reached, but none of the logged-in

 

 

users is an Administrator, the first Administrator user to

 

 

arrive is granted access, and the system terminates the

 

 

non-Administrator session that’s been idle the longest.

 

 

Active sessions per

Specify the number of simultaneous login sessions per

user

 

user ID or select Unlimited.

 

 

Session timeout

Specify the length of time after which the system

(minutes)

 

terminates a session for inactivity or select Unlimited.

 

 

 

See also:

“System Security” on page 35 “Login Policy Settings” on page 57

Local User Account

The Local User Account page lets you increase system security by:

Locking out users who have exceeded the specified number and frequency of login failures. The system locks the account either indefinitely or for the length of time you specify.

Disabling accounts that have been inactive a specified number of days. The following table describes the fields on the Local User Account page.

Table 3-8

Fields on the Local User Account page

 

 

 

Field

 

Description

 

 

Account Lockout

 

 

 

Enable account lockout

Turns on lockout feature and enables lockout

 

 

configuration fields below.

 

 

Failed login threshold

Specify how many consecutive login failures cause the

 

 

system to lock an account.

 

 

Failed login window

Specify the time span within which the consecutive

(hours)

 

failures must occur in order to lock the account.

 

 

 

Polycom, Inc.

59

Page 71
Image 71
Polycom 3725-76302-001LI manual Local User Account, Field Description Account Lockout