Preliminary/Postliminary Scripting

Call Server Configuration

 

 

Script Debugging Dialog Box for Preliminaries/Postliminaries

The Script Debugging dialog box lets you test a Javascript executable script that you’ve added as preliminary to a dial rule or as a postliminary for an external gatekeeper, SIP peer, SBC, or MCU. It lets you specify parameters of a call and the dial string, and see what effect the script has on the dial string.

The following table describes the fields in the Script Debugging dialog box. Table 10-12Script Debugging dialog box

Field

Description

 

 

Dial string

This is the DIAL_STRING variable in the script, which is

 

initially set to the dial string being evaluated. Enter a dial

 

string to test. Alternatively, provide the entire SIP

 

INVITE message. Then click Execute Script.

 

Note: For SIP, the script should always specify the

 

schema prefix (sip or sips). For instance:

 

DIAL_STRING = "sip:xxx@10.33.120.58"

 

 

Caller site

Select a site in order to set the first four caller variables.

 

 

Caller variables

Lists variables that can be used in the script to

 

represent caller alias values. Enter an alias value to test

 

for that variable.

 

 

Final result

Displays the outcome of running the script.

 

For a dial rule preliminary, if the script rejected the dial

 

string (skipping the dial rule action and passing it on to

 

the next dial rule), a message tells you so. Otherwise,

 

the transformed dial string is displayed.

 

 

Script output

Displays any output produced by the script (e.g.,

 

println statements).

 

 

Output SIP headers

For an external SIP peer’s postliminary, displays the

 

headers produced by the script.

 

 

See also: