DMA Operations Guide

Signaling Settings

 

 

See xmpp.org for more information.

Signaling Settings Fields

The following table describes the fields on the Signaling Settings page.

Table 4-5

Fields on the Signaling Settings page

 

 

 

Field

 

Description

 

 

H.323 Settings

 

 

 

Enable H.323 signaling

Enables the system to receive H.323 calls.

 

 

Caution: Disabling H.323 terminates any existing H.323

 

 

calls. When you click Update, the system prompts you

 

 

to confirm.

 

 

 

Status

 

Indicates whether the system’s H.323 gatekeeper

 

 

functions are active.

 

 

 

H.225 port

 

Specifies the port number the system’s gatekeeper uses

 

 

for call signaling.

 

 

We recommend using the default port number (1720),

 

 

but you can use any value from 1024 to 65535 that’s not

 

 

already in use and is different from the RAS port.

 

 

 

RAS port

 

Specifies the port number the system’s gatekeeper uses

 

 

for RAS (Registration, Admission and Status).

 

 

We recommend using the default port number (1719),

 

 

but you can use any value from 1024 to 65535 that’s not

 

 

already in use and is different from the H.225 port.

 

 

H.245 open firewall

Shows the port range used for H.245 so you can

ports

 

configure your firewall accordingly. This is display only.

 

 

H.323 multicast

Enables the system to support gatekeeper discovery

 

 

(GRQ messages from endpoints) as described in the

 

 

H.323 and H.225.0 specifications.

 

 

Enable H.323 device

Check the box to turn on H.323 device authentication.

authentication

Click Device authentication settings to go to the

 

 

Device Authentication page and add authentication

 

 

credentials (see “Device Authentication” on page 264).

 

 

SIP Settings

 

 

 

Enable SIP signaling

Enables the system to receive Session Initiation

 

 

Protocol (SIP) calls.

 

 

Caution: Disabling SIP terminates any existing SIP

 

 

calls. When you click Update, the system prompts you

 

 

to confirm.

 

 

 

74