Chapter 8 SXYX
Replacement period
The harmonic drive replacement period is determined by the total number of wave generator rotations. A calculation example is shown below.
The recommended harmonic drive replacement period is 8.4⋅108 rotations (at usage atmospheric temperature range 0°C to +40°C).
The harmonic drive should be replaced earlier if the robot operation duty is high or if the temperature conditions are poor.
[Replacement period] =8.4⋅108/(n⋅60⋅h⋅D⋅N⋅θ) years
n: Number of robot movements in one minute
θ : Average axis rotation in one movement
N : Deceleration rate (50 for ZRS 
h : Number of operation hours per day
D : Number of operation days per year
(Example) The YK500X 
n  | : 10  | 
θ  | : 0.25  | 
N  | : 50  | 
h  | : 24  | 
D  | : 240  | 
[Replacement period] | =8.4⋅108/(n⋅60⋅h⋅D⋅N⋅θ)  | 
  | =8.4⋅108/(10⋅60⋅24⋅240⋅50⋅0.25)  | 
=19.4 years
Consult with YAMAHA when actually replacing the harmonic drive.