Chapter 12 HXYLX
3)Remove the harness retainer located at the cable carrier outlet. (Hexagon socket bolt M5, 2 bolts)
Harness retainer
4) Pass the required wires and pipes through the cable carrier.
The cable carrier has an outer lid that can be opened and closed easily. Use a
5)Open the cover of the
6)
!CAUTION
1.The wires could be damaged if the harness retainer is tightened too much.
2.Manually move the robot by the full stroke before fixing to confirm that the harness and air tube, etc., are not pulled in the cable carrier. These could be damaged if pulled during operation.
When completed with the wiring, fix with the harness retainer in the wiring box.
7)
!CAUTION
Take care not to catch the harness or air tube with the cover.