Chapter 6 PXYX

2-2 Ground wire

Use an AWG14 (2.0mm2) or larger ground wire with a total length of 1m or less. Crimp an M4 ring-tongue terminal on the end of the wire connected to the robot.

2-3 Wiring method

WARNING

Accurately insert the lock washer between the ring-tongue terminal and robot.

Proper continuity may not be secured if the lock washer is dislocated.

Connect the ground wire to the ground terminal located on the end face of the X- axis wiring box.

An M4 small screw with spring washer and lock washer are attached to the ground terminal. Arrange the parts in the order of the lock washer, ring-tongue terminal and M4 small screw with spring washer, and then tighten them. (Refer to Fig. 6- 3)

M4 small screw with spring washer

Ring-tongue terminal

Lock washer

Fig. 6-3

6-4

Page 92
Image 92
Yamaha 4-axis model, 3-axis model owner manual Ground wire, Wiring method