Chapter 9 MXYX
2) Turn the controller power OFF.
NOTE
When the ZF unit is attached for the
3)Place a sign indicating "Work In Progress" so that other operators do not turn the controller power ON.
4)Remove the stroke cover of the axis to which grease is to be replenished.
5)Install the grease nipple on the M6 tap on the ball screw flange surface.
6)Using a grease gun, replenish grease from the grease nipple.
Sufficient grease has been replenished when new grease starts to seep out to the screw shaft.
Wipe off any excessive grease.
Recommended grease gun : MG70 (THK H-type nozzle)
7)Remove the grease nipple.
8)Return the stroke cover to the original position.