Chapter 6 PXYX

7) When completed with the wiring, reattach the cover to the wiring box.

Cable carrier specifications

!CAUTION

When setting the harness and air tube into the cable carrier, make sure that the total cross-sectional area of all wires and pipes, including the YAMAHA cable, inside the cable carrier does not exceed 30% of the cable carrier’s cross-sectional area.

The cross-sectional shape of the cable carrier, and the shape of the cable mounted initially by YAMAHA are shown below.

Power wire φ7.6

Signal wire φ8.2

19

25

50

62

Fig. 6-5

6-7

Page 95
Image 95
Yamaha 3-axis model, 4-axis model owner manual Cable carrier specifications