Chapter 11 FXYBX/SXYBX
4)Using a grease gun, replenish grease from the grease nipple installed on the linear guide bearings.
Sufficient grease has been replenished when new grease starts to seep out from the clearance between the linear guide bearings and rail.
FXYBX
X-axis, Y-axis
The
Recommended grease gun : MG70 (THK)
SXYBX
The
Wipe off any excessive grease that has seeped out to the rail.
Recommended grease gun : MG70 (THK)
Z-axis (ZF)
One linear guide bearing is attached. A grease nipple is attached to the counter- motor side of the slider, so move the slider to the motor side and then start the work.
Recommended grease gun : MG70 (THK)
5)Install the stroke cover.
Confirm the surrounding safety, and then turn the controller power ON.