12-15
Chapter 12 HXYLX
4 User Wiring and User Piping
WARNING
Always turn off the controller before wiring and piping to prevent electri-
cal shocks.
4-1 Cable carrier type
A cable carrier is mounted as a standard between the X and Y axes. When 3rd-
axis are used, a cable carrier is also provided between the Y and Z axes, and when
using 4th-axis, a cable carrier is also provided between the Z and R axes. Lay the
wiring and piping to the tool using these ducts. A 0.3sq 10-core flexible cable is
wired from the X-axis wiring box to the final axis wiring box, and can be used
freely. The wiring and piping methods for a 2-axis arm type are explained below
as an example.
4-1-1 Example of wiring and piping methods using cable carrier
1) Remove the four M4 small screws and open the X-axis wiring box (fixed)
cover.
2) Pass the required cables and air tubes, etc., through the cable lead-out port on
the X-axis wiring box (fixed).
Cable lead-out port
Fig. 12-12