Chapter 6 PXYX

5 Periodic Inspections

The inspection periods and general precautions are described in Chapter 4 Peri- odic Inspections. Always refer to that Chapter before starting this work.

WARNING

Always turn the controller power OFF before starting periodic inspec- tions. Serious accidents could occur if the robot starts moving during the periodic inspection.

5-1 Replenishing grease to the linear guide

Grease must be replenished to this linear guide periodically. Select the grease from the following recommended types.

Recommended grease : Alvania No. 2 (Showa Shell)

Daphne Eponex No. 2 (Idemitsu)

!CAUTION

When designated by YAMAHA and the user, special grease, such as splatter- proof grease, may be applied when the robot is delivered. In this case, apply the appropriate grease as indicated in the delivery specification drawings, etc.

1)Turn the controller power OFF.

2)Place a sign indicating "Work In Progress" so that other operators do not turn the controller power ON.

3)Remove the side cover. (Refer to 1-4. Installation.)

4)Apply grease onto the linear guide with a finger.

5) After greasing, return the side cover to the original position.

6-8

Page 96
Image 96
Yamaha 4-axis model, 3-axis model owner manual Periodic Inspections, Replenishing grease to the linear guide