The patch MIB (CISCO-OPTICAL-PATCH-MIB) assists SNMP monitoring of patch connections. To
enable the SNMP trap notifications for patch connection creation, modification, and deletion, use the
following global configuration command.
For information about other commands that enable SNMP tr ap no tificati ons, r ef er t o the
Cisco IOS Configuration Fundamentals Command Reference publication.
Example
The following example shows how to enable SNMP trap notifications for patch c onnec tio ns:
Switch# configure terminal
Switch(config)# snmp-server enable traps patch
Physical Topology MIB
The network physical topology MIB (PTOPO-MIB) assists SNMP monitoring of network t opo logy
activity. To enable the SNMP trap notifications for network topology activity, use the following global
configuration command.
For information about other commands that enable SNMP tr ap no tificati ons, r ef er t o the
Cisco IOS Configuration Fundamentals Command Reference publication.
Example
The following example shows how to enable SNMP trap notifications for network topo lo gy ac tivity:
Switch# configure terminal
Switch(config)# snmp-server enable traps topology
Redundancy Facility MIB
The redundancy facility MIB (CISCO-RF-MIB) assists SNMP monitoring of processor redundancy
activity. To enable the SNMP trap notifications for processor redundancy activity, use the following
global configuration command.
Command Purpose
snmp-server enable traps patch Enables SNMP trap notifications for patch connection
activity.
Command Purpose
snmp-server enable traps topology
[throttle-interval seconds]Enables SNMP trap notifications for network topology
activity.
Command Purpose
snmp-server enable traps rf Enables SNMP trap notifications for the redundancy facility
activity.