A-204
Cisco ONS 15530 Configuration Guide and Command Reference
78-14227-01, Cisco IOS Release 12.1(10)E2
AppendixA Command Reference
System Management Commands
show temperature
To display shelf temperature information, use the show temperature command.
show temperature
Syntax Description This command has no other arguments or keywords.
Defaults None
Command Modes EXEC and privileged EXEC
Command History
Usage Guidelines Use this command to display the current shelf temperature and the alarm threshold temperatures.
Examples The following example shows how to display internal redundancy software state inf or mat ion. (Se e
Table A -41 for field descriptions.)
Switch> show temperature
Sensor Temperature Thresholds
(degree C) Minor Major Critcal Low
-------------------- ----------- ------------------------------------
Sensor 27 65 75 80 -15
Sensor Alarms
Minor Major Critical
-------------------- ------------------------
Sensor 0 0 0
Release Modification
12.1(10)EV2 This command was introduced.
TableA-41 show temperature Field Descriptions
Field Description
Sensor Shows the type of sensor.
Temperature (degree C) Shows the current temperature in degrees Celsius.
Minor Shows temperature threshold that generates a minor alarm.
Major Shows temperature threshold that generates a major al arm.
Critical Shows temperature threshold that generates a critical alarm.
Low Shows temperature threshold that generates a low alarm.
Alarms Shows the number of minor, major, and critical alarms on the inlet and
outlet sensors.