9-19
Cisco ONS 15530 Configuration Guide and Command Reference
78-14227-01, Cisco IOS Release 12.1(10)EV2
Chapter9 Monitoring Your Netw ork Topology
Monitoring Without the OSC or In-Band Message Channel
For information about other commands that enable SNMP tr ap no tificati ons, r ef er t o the
Cisco IOS Configuration Fundamentals Command Reference publication.
Example
The following example shows how to enable SNMP trap notifications for processor redundancy activity.
Switch# configure terminal
Switch(config)# snmp-server enable traps rf
Monitoring Without the OSC or In-Band Message Channel
To take advantage of the OSC, the Cisco ONS 15530 system must be equipped with oneOADM module
with OSC (for unprotected configurations) or two OADM modules with OSC (for pr otec te d
configurations). Likewise, to take advantage of the in-band message channel, the system must be eq uiped
with a 10-Gbps ITU trunk card or a 10-GE uplink card. I f y our sy stem i s n ot e qu ippe d to su pport the
OSC or in-band message channel, the following conditions apply:
You cannot reach other nodes on the network using Telnet or SNMP. Separate connections to each
system must exist on the network for management purposes.
CDP does not function on the network. The physical topology must be configured manually for fault
isolation and system management.
Keepalive information is not available for other nodes on the network.

Setting up Connections to Individual Nodes

To access individual nodes in a Cisco ONS 15530 network without the OSC, you must establish separate
connections to a management port on each system. This ca n be d one u sing a Telnet session over an
Ethernet connection, a console connection, or a modem connection to the auxiliar y port. F or instr uctions
on how to do this, see Chapter 3, Initial Configuration.
For NMS without the OSC, each node reports individually to the NMS. Thus you must connect the N MS
to each node using SNMP over an Ethernet connection.