5-5
Cisco ONS 15530 Configuration Guide and Command Reference
78-14227-01, Cisco IOS Release 12.1(10)EV2
Chapter5 Configuring Transponder L ine Card Interfaces
Configuring Protocol Encapsulation or Clock Rate
Note Use the encapsulation command for clock rates supported by protocol monitoring rath er tha n the
clock rate command. For more information protocol monitoring, see the About Protocol
Monitoring section on page5-7.
Note When you must use Sysplex CLO encapsulation or Sysplex ETR encapsulation, you must configure
APS bidirectional path switching. For more information on APS and bidirectional path switching,
see Chapter 7, About Splitter Protection.
Examples
The following example shows how to configure GE (Gigabit Et hern et ) en caps u lat ion on a t rans parent
interface:
Switch(config)# interface transparent 10/0/0
Switch(config-if)# clock rate 1065
Note Removing the protocol encapsulation or the clock rate does not shut down the transmit lasers. To shut
down the lasers, use the shutdown command.
Displaying Protocol Encapsulation or Clock Rate Configuration
To display the protocol encapsulation configuration of a transparent interface, use the following EXEC
command:
Examples
The following example shows how to display the protocol encapsulation configuration of a transpare nt
interface:
Switch# show interfaces transparent 8/0/0
Transparent11/3/0 is administratively up, line protocol is up
Encapsulation: GigabitEthernet
Signal monitoring: off
Time of last "monitor" state change never
Time of last "encapsulation" change 00:00:03
Forward laser control: Off
Configured threshold Group: None
Loopback not set
Last clearing of "show interface" counters 00:00:03
Hardware is transparent
Command Purpose
show interfaces transparent slot/subcard/0 Displays the transparent interface configuration.