Configuration

Proportional Output), Pulse Frequency (Pulse Frequency Type), Frequency Prop (Frequency Proportional), or On/Off type and associated parameters.

Alarms Configuration ( Table 6-8) - configure Alarm 1 through 4 for Alarm’s Source and associated parameters.

Monitors Configuration (Table 6-9) – configure Monitor 1 through 4 for Monitor Type, Source and associated parameters.

Math Configuration (Table 6-10) – configure Math 1, 2, 3, and 4 for Input Source, Math Type, and associated parameters.

Logic Configuration ( Table 6-11) – configure Logic 1, 2, 3, and 4 for Input Sources, Type, and associated parameters.

Auxiliary Configuration (Table 6-12) – configure Switch 1, Switch 2, Function Generator 1 and Function Generator 2(for pre-control linearizing of inputs) for Sources and associated parameters.

PID Control (Option) Configuration (Table 6-13)configure: PID 1 and PID 2 Configuration parameters,

Tune (Enable Accutune, Fuzzy Logic, Use Prop Band, Use RPM, configure Tuning parameters) and

Alarms Parameters (Setpoint types and Values, alarm hysteresis)

Auto Cycling (Table 6-16) – enable Auto Cycle 1 and 2 and set rinse schedule and associated parameters. Auto cycling provides automated timing, control and functionality for the cleaning and calibration of input probes.

Variables (Analog Table 6-3 and Digital Table 6-4)selections can be read and written remotely using Modbus function codes. You are setting up the initial values for the variables when power is applied to the UDA (Refer to Table 6-18 for an Example)

Communication Configuration (Table 6-19) – configure IR Front Panel,

Modbus, RS485 and Ethernet.

Maintenance Configuration (Table 6-20) – Configure:

System - read the Software version, configured Language, selected Mains Frequency, and PID Control Selections, enter a Password, and reset the Unit.

Input 1 and Input 2 - configure Input types, Conductivity units’ type, wire size, and wire length, and temperature Units.

Display – setup the Main Display Header; and Clear Event and Cal Histories.

Tag Names – configure tag name strings for input names on single channel main display, Auto Cycle display header, Pharma display header, PID display header. Alarm names to appear in status and event history.

Clock - set real time clock date; time; date format; and time format.

Tests - run Display and Keyboard tests, read Output levels, and read Relay States.