Service Calibrations

Recovery through the Front Panel and retry the Printhead Alignment.

10Once the complete Line Sensor calibration is completed successfully, OK will be displayed on the Front Panel.

Carriage PCA

The purpose of this Service Calibration is to reset the ink short thresholds after replacing the Carriage PCA. This calibration is integrated into the Scan Axis diagnostic test. See 4. Carriage Assembly on page 3-26.

Perform the Carriage Setup as follows:

1In the Service Calibrations submenu, scroll to Carriage PCA and press OK.

2To calibrate the Carriage PCA, run the Carriage Assembly diagnostic test. See 4. Carriage Assembly on page 3-26.

4-18

HP Designjet T Series — Service Manual