Service Calibrations
Recovery through the Front Panel and retry the Printhead Alignment.
10Once the complete Line Sensor calibration is completed successfully, OK will be displayed on the Front Panel.
Carriage PCA
The purpose of this Service Calibration is to reset the ink short thresholds after replacing the Carriage PCA. This calibration is integrated into the Scan Axis diagnostic test. See 4. Carriage Assembly on page
Perform the Carriage Setup as follows:
1In the Service Calibrations submenu, scroll to Carriage PCA and press OK.
2To calibrate the Carriage PCA, run the Carriage Assembly diagnostic test. See 4. Carriage Assembly on page