Removal and Installation

Scan-Axis Motor (T1100/T1100ps/T610)

Removal

Switch off the printer and remove the power cable.

1. Remove the Right Cover on page 6-27.2. Remove the Left Cover on page 6-30.

3. Loosen the T-10 uncapping screw sufficiently so you can manually move the

Carriage Assembly in step 4.

If you are uncapping a 44 inch printer, you will need to use either a very long or very short screwdriver to loosen the uncapping screw. In this way, you can loosen the screw and pass the rewinder motor.

44 inch T1100 printer shown (with Rewinder)

4. Push the Carriage Assembly into the print path.

5. Loosen the T-15 screw Belt Tensioner to the printer to remove the tension from the belt.

6-142

HP Designjet T Series — Service Manual