Blanking Test

This test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater than 0.82 over its maximum upper weight limit is placed upon the unit.

1.Place weights that total the upper limit plus 0.82 kilograms on the weigh platter. For example: If the upper limit is set at 15 kilograms, place weights equaling 15.82 kilograms.

2.Verify that the display shows a dash and three hyphens ( _ - - -). This is the overweight indication.

The scanner/scale may blank (show an underscore and three hyphens) at any

weight greater than its upper limit, but must blank when the upper limit plus 0.82 pounds are set upon the weighing surface.

NOTE

5-14

Magellan® 9500

Page 114
Image 114
Datalogic Scanning 9504, 9500 manual Blanking Test