RS-232 NAK Character

This feature specifies which ASCII character will be used as a NAK char- acter.

NOTE

DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits.

To specify the RS-232 NAK Character:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET RS-232 NAK CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the hex designation for the desired character. A table contain- ing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for the desired character. For example, if ASCII “A” were the desired NAK character, you would scan the digits “4”, then “1” (the ASCII corre- sponding hex value).

4.The scanner will automatically exit Programming Mode when the appropriate amount of digits/characters have been scanned.

SET RS-232 NAK CHARACTER

6-102

Magellan® 9500

Page 218
Image 218
Datalogic Scanning 9504, 9500 manual RS-232 NAK Character, 102