Code 39
•Check character must be included in label data.
•Label length including start, stop and check characters and exclud- ing prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•Start and stop characters "*" must be included in label.
•Prefix must be an ASCII character '*'.
•Example : '**Code 39.TEST*'.
Code 39-Pharmacode
•Check character must be included in label data.
•Label length including start, stop and check characters and exclud- ing prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•Start and stop characters "*" must be included in label.
•Prefix must be an ASCII character 'p'.
•Example: 'p*123456789*'.
I 2 of 5
•Check character must be included in label data.
•Label length including check characters and excluding prefix charac- ter must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•Prefix must be an ASCII character 'i'.
•Example: 'i0123456789'.
Product Reference Guide |