Set-Up & Installation

3.Hook the fingers of both hands into the lift handles. The first is located along the inside of the front scanner wall, and the second is behind the scanner hood, as shown in Figure 2-23.

DO NOT attempt to lift the unit using the EAS Antenna, plastic edges, scale frame, or any features other than the lift handles.

CAUTION

4.Lower the unit into the counter opening, ensuring that none of the cables are pinched, pierced or crimped.

5.Re-install the All Weighs™ Platter and verify that it is flush or just below flush with the countertop. This is necessary to provide smooth scanning from either direction. Make adjustments as needed to align the platter with the counter by moving support rails up or down, or consider installing screws in positions that will allow their use in adjusting the unit’s position.

Failure to install a scanner/scale in a stable and level position will inhibit

weighing, calibration and zeroing operations. The platter MUST make unob- structed contact with all of its supports for proper weighing operation.

NOTE

6.Once installation is complete, proceed with the Operational Verifica- tion procedures that follow.