EAS Features
EAS Beep Duration
Sets the duration of the EAS successful deactivation beep, specified in 10ms increments. The beep only occurs if EAS mode is not disabled.
To set the EAS Beep Duration:
1.Scan the SWITCH bar code.
2.Scan the bar code, SET EAS BEEP DURATION below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired EAS Beep Duration. The selectable range is 0- 255, which is the timeout in
Examples:
000 = EAS beep disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4.Complete the programming sequence by scanning the SWITCH bar code.
SET EAS BEEP DURATION
Product Reference Guide |