MSI/Plessey Check Character Calculation

Enables/disables calculation and verification of optional MSI/Plessey check characters.

If check character calculation is disabled, the risk is increased that a misread

can occur. When disabled, any check characters in a bar code are treated as data characters.

NOTE

To set this feature:

1.Scan the SWITCH bar code.

2.Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Complete the programming sequence by scanning the SWITCH bar code.

MSI/PLESSEY CHECK CHARACTER CALCULATION = DISABLE

MSI/PLESSEY CHECK CHARACTER CALCULATION = ENABLE

6-258

Magellan® 9500

Page 374
Image 374
Datalogic Scanning 9504, 9500 manual MSI/Plessey Check Character Calculation, 258