Code 39 Enable

Code 39 Maximum Label Length

This feature specifies the maximum allowable length of a Code 39 label.

 

Length in this case includes check, data and ASCII characters, but does not

 

include start, or stop characters. This feature applies when Code 39 Length

 

Control is set to variable-length decoding.

NOTE

Maximum label length should be greater than or equal to minimum label

length.

 

To set this feature:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET CODE 39 MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the fac- ing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired maximum label length. The selectable range for this option is 00 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (00-50).

4.Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 39 MAXIMUM LABEL LENGTH

Product Reference Guide

6-199

Page 315
Image 315
Datalogic Scanning 9500, 9504 manual Code 39 Maximum Label Length, To set this feature Scan the Switch bar code