Interface Related Features

Interface Related Features

Interface Type

Specifies the current scanner interface. Selections are:

INTERFACE TYPE

 

INTERFACE IDENTIFICATION NUMBERa

RS-232

Standard

 

05

 

 

 

 

RS-232

Wincor-Nixdorf

 

12

 

 

 

 

RS-232

Single Cable

 

20

 

 

 

IBM USB

 

45

 

 

 

IBM Port 17

 

04

 

 

 

 

 

 

NOT USER-SELECTABLE

 

 

 

 

Null Interface

 

Indicated by 7-segment FRU display flashing

 

0 at start-up

 

 

 

 

 

 

 

a.To access a scanner’s interface identification number, place the scanner in Scanner Diagnostic Mode and view the 7-segment FRU display (reference Scanner Diagnostic Mode in Chapter 2 for more information).

NOTE

NOTE

A new scanner may have been shipped from the factory with a Null Interface (no interface type selected) to ensure system compatibility at installation. In this case, the correct Interface Type programming bar code must be scanned first before the scanner can be used with a POS system.

If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Selecting an interface type resets ALL other configuration items to the fac- tory default for that interface type.)