EAS Deactivation Duration — Manual

Specifies the amount of time EAS deactivation is operative upon pushing the Manual EAS Deactivation Push Button.

This setting pertains only to units configured for EAS Coupled Mode. Refer-

ence the “EAS Mode ” description for more information about Coupled and Decoupled EAS operation. Also reference “EAS Retry Count .”

NOTE

To set the EAS Deactivation Duration — Manual:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET EAS DEACTIVATION DURATION — MANUAL below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired duration. The selectable range is 1-255, which is the duration in 50-millisecond increments. Pad all single and double digit numbers with leading zeroes to yield a 3-digit entry (001-255). Examples:

001 = 50ms

008 = 400ms

050 = 2,500ms (2.5 seconds)

The scanner will automatically exit Programming Mode when the appro- priate amount of digits have been scanned