MSI/Plessey Enable

MSI/Plessey Fixed Length 2

This feature specifies MSI/Plessey second fixed length.

This applies when MSI/Plessey Length Control is set to fixed-length decod- ing.

NOTE

If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.

 

To set this feature:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired fixed label length. The selectable range for this option is 0 (zero), or 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (00, 04-16).

4.Complete the programming sequence by scanning the SWITCH bar code.

SET MSI/PLESSEY FIXED LENGTH 2

Product Reference Guide

6-267

Page 383
Image 383
Datalogic Scanning 9500, 9504 manual This feature specifies MSI/Plessey second fixed length