Code 39 Enable

Code 39 Check Character Calculation

 

Enables/disables calculation and verification of an optional Code 39 check

 

character. When disabled, any check character in label is treated as a data

 

character.

 

If check calculation is disabled, the risk is increased that a misread can

 

occur.

 

In particular, if you are using variable length stitching, it is important to use

NOTE

check character calculation to prevent misreads.

To set this feature:

1.Scan the SWITCH bar code.

2.Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Complete the programming sequence by scanning the SWITCH bar code.

CODE 39 CHECK CHARACTER CALCULATION = DISABLE

CODE 39 CHECK CHARACTER CALCULATION = ENABLE

Product Reference Guide

6-193

Page 309
Image 309
Datalogic Scanning 9500, 9504 manual Code 39 Check Character Calculation