Chapter 5

Calibration

A number of situations require the scale to be calibrated. They are:

at initial installation of the scanner/scale

if the scale cannot be re-zeroed

if you change the weight measure from pounds to kilograms or vice- versa

if diagnostics indicate a calibration error

the weigh module has been replaced

Follow the procedures on the following pages to ensure that the scanner/ scale will meet Weights and Measurement requirements.

LEGAL NOTE

Certification of the scanner/scale’s weighing apparatus is subject to Fed- eral, State and Local Weights and Measures statutes and is restricted to authorized government agencies and/or duly registered agents thereof. Anytime a scale is calibrated, it should be properly sealed with a lead and wire or paper seal before being placed into service.

It is your responsibility to check with the appropriate authorities in your area to ensure compliance with pertinent regulations before removing any official seals or placing a newly calibrated scanner/scale into ser- vice.