Scale Enforced Zero Return

This feature enables/disables the enforced zero return of the scale. Three settings are available for this feature:

Disable

Scale Must Return to Zero Weight Within Four Minutes — Scale will require re-zeroing if a non-zero weight is left on for more than 4 minutes

Scale Must Return to Zero Weight Between Weight Requests — Re- zeroing required if weight doesn't return to zero between weight requests from the POS, plus scale will require re-zeroing if a non- zero weight is left on for more than 4 minutes.

To set this feature:

1.Scan the SWITCH bar code.

2.Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. The strategy is to select the lowest possible filter level needed that allows normal scale operation.

3.Complete the programming sequence by scanning the SWITCH bar code.

SCALE ENFORCED ZERO RETURN = DISABLE

6-36

Magellan® 9500

Page 152
Image 152
Datalogic Scanning 9504, 9500 manual Scale Enforced Zero Return