Single Cable RS-232 RTS CTS Selection

Specifies how RTS and CTS are used to control the data flow. RTS is con- trolled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the con- figuration values state, to determine when to send label data.

Choices are:

Option 0 = RTS is held in low state and CTS is ignored

Option 1 = RTS is held in high state and CTS is ignored

Option 2 = Assert RTS and wait for CTS to be asserted

Option 3 = Assert RTS and ignore CTS

Option 4 = RTS held low, wait for CTS to be asserted

Option 5 = RTS held high, wait for CTS to be asserted To set this feature:

1.Scan the SWITCH bar code.

2.Scan a bar code below or on the following pages representing the desired option. You’ll need to cover any unused bar codes, as well as facing pages to ensure that the scanner reads only the bar code you intend to scan.

3.Complete the programming sequence by scanning the SWITCH bar code.

RTS CTS SELECTION = OPTION 0

RTS CTS SELECTION = OPTION 1

6-112

Magellan® 9500

Page 228
Image 228
Datalogic Scanning 9504, 9500 manual Single Cable RS-232 RTS CTS Selection, 112