6-60 Magellan® 9500

Interface Type — continued

To select the desired interface:
1. Disconnect current interface cable(s) if currently connected.
2. Scan the SWITCH bar code
3. Scan the bar code representing the appropriate interface located on
the following pages. Youll need to cover any unused bar codes adja-
cent to and on any facing pages to ensure the scanner reads only the
bar code you intend to scan.
4. Complete the programming sequence by scanning the SWITCH
bar code.
5. Connect new interface cable(s).
CAUTION
Great care should be taken to select the correct interface type, since you can
cause damage to the scanner and/or POS terminal by attempting to change
to an incompatible interface. ALWAYS make interface selections with the
host cable DISCONNECTED.
NOTE
When an interface is selected, the scanner loads the factory configuration
for that interface as the selection is made, erasing any and all custom config-
uration that may have previously been done.
NOTE
Once the correct interface has been set, it will be necessary to proceed to
the appropriate pages in this manual that select parameters and options for
that interface. For example, if RS-232 is selected, turn to the pages in this
manual headed as features specific to the RS-232 interface.