Manuals
/
Datalogic Scanning
/
Computer Equipment
/
Scanner
Datalogic Scanning
manual
Magellan 9500/9500Ω 9504/9504Ω
Models:
9504
9500
1
1
460
460
Download
460 pages
3.45 Kb
1
2
3
4
5
6
7
8
Specs
Install
Error messages
Flowcharts
Error Reporting
RS-232 Intercharacter Delay
Symbology Programming
EAS Deactivation Indicators
Wire Requirements
Dimension
Page 1
Image 1
Magellan
®
9500/9500
Ω
9504/9504
Ω
with SmartSentry
®
Product Reference Guide
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Magellan 9500/9500Ω 9504/9504Ω
Datalogic Scanning, Inc
Table of Contents
Operation and Maintenance
Programming
101
UPC/EAN AIM ID
176
5 AIM ID
Appendix A. LED/Beeper Indications & Controls
Datalogic SCANNING, INC. Magellan END User License Agreement
END
Manual Overview
Chapter Introduction
How to Use This Manual
Avoid damage to equipment and/or property
Manual Conventions
Scanner/Scale Nomenclature
Scanner and Scanner/Scale Nomenclature
Scale Host Power EAS Port
Connectors
Scanning
Physical Parameters
Deactivating EAS Tags
Maximum Static Weight Overload
Rated Weight Capacity
Automatic Zero Maintenance
Weighing
User Configurable Warm-up
Power-up
Warm-Up Time
Thermal Equilibrium
Environmental Specifications
Power Supply
Electrical Specifications
Laser and Product Safety
Safety precautions to be taken
Labeling
Regulatory, reference and safety labeling is shown in Figure
Country Compliance Comments
Agency Compliances
Bar Codes Supported
Magellan
Chapter
Models
Pre-Installation Considerations
Checkstand Design
Scanner Maintenance
Scanner Installation
References
Scanner Usage
Site Preparation Overview
Magellan
Vertical Clearance
Ventilation and Spacing
Debris Chutes/Ventilation Slots
Service Access
Grounding
Power Installation
Checkstand Preparation
Installation Overview
Liquid Spills and Moisture
Counter Cutout
Counter Cutout
Typical Checkstand Design & Cutout Location
Dimensions
20.125 51.12cm 18.625 47.30cm 11.625 29.53cm 9cm
Cutout Dimensions Minimum Required Counter Cutout
Checkstand Mounting
Installation Overview
Checkstand Vibration
Following text describes each of these steps
Unpacking
Proceed to the Operational Verification instructions below
Operational Verification
Product Reference Guide
Magellan
Blank or a
Scanner Diagnostic Mode
Diagnostic Modes
Cables & Connections
Scale Diagnostic Mode
11. Cable Routing
Lighting Considerations
Remote Scale Display Placement/Installation
00 lb
Viewing Angle
Short Pedestal Base only
Placing and Installing the Remote Scale Display
14. Physical Measurements Remote Display Short Base
15. Remote Scale Display Components
Legal Note
Changing Weighing Modes
EAS Considerations
Set-Up & Installation
Product Flow
Swapping Position EAS Single-Antenna only
19. Locating the EAS Single-Antenna Left-to-Right
ON/OFF
Set-up
21. Connecting Cables to the Scanner/Scale
Vertical Bezel
Installation
Product Reference Guide
Do not use
System Power-Up Recap
Problem Isolation
Scanning Items
Chapter Operation Maintenance
Scan Zone
Proper Scanning Technique
EAS Deactivation Modes
Deactivating Security Labels
Manual EAS Deactivation Push Button
EAS Deactivation Indicators
Proper Weighing Technique
L-Shaped Platter & Item Placement
Power-Up/Selftest
Power-Up/Selftest & Pre-Operation
Operational Controls
Operational Modes
Operational Configuration
Error Reporting
Normal Operation
Operating Mode
Scanner and Scale Reset
Diagnostic Mode
Sleep Mode
Additional Functions
Zeroing the Scale
Scale Adjustments
You have completed the scale zeroing function
Calibrating the Scale
Operational Maintenance
Platter Removal
Vertical Scan Window Replacement
Vertical Scan Window Removal/Replacement
Horizontal Scan Window Replacement WRG
Removing/Replacing the WRG Window
Power-Up Selftest
Problem Isolation
Diagnostic Tests
Diagnostic Procedures
Operational Tests
Error Codes
Error Probable Cause Code
Action Required
Scale Error Reporting
Lamp Description
Flowcharts
Problem Isolation Start
Problem Isolation Selftest
Problem Isolation Poor/No Reading
Problem Isolation No Transmit to POS
Problem Isolation Scale
Problem Isolation Remote Display
Problem Isolation EAS System
Magellan
Chapter Calibration
Description of Calibration Sequence
Motion Test
Automatic Zero Setting Test
Calibrating the Scale Pounds & Kilograms
Preparing the Scanner/Scale for Calibration
Calibration Cover
Reinstall the weigh platter
Yellow LED will extinguish for approximately 10 seconds
You have completed the Increasing-Load Test Phase
Increasing-Load Test Phase
Calibration Verification U.S. Pounds
Shift Test
Shift Test
Blanking Test
Increasing- Load Test Phase
Return to Zero Test
Decreasing-Load Test
Calibration Verification Kilograms
Shift Test Metric
European Shift Test Metric
Blanking Test
Decreasing-Load Test
Magellan
Understanding the Basics
Introduction to Label Programming
Customizing Your Scanner’s Operation
Integrating the Scanner With Your Host System
Integrating the Scanner With Your Host Sys
Programming via Handheld Device
Programming Overview
Entering and Exiting Programming Mode
What Is Programming Mode?
Will be implemented
Programming Session
Programming Overview
Programming Sequence
Programming Sequence
Return to Factory Settings
LED and Beeper Indicators
If You Make a Mistake
Test Mode
Double Read Timeout
General Scanner and Scale Features
Double Read Timeout = 1 Second
Laser Timeout
Laser Timeout = 10 Minutes Laser Timeout = 15 Minutes
Motor Timeout
Motor Timeout = 10 Minutes Motor Timeout = 15 Minutes
Motor Timeout = 30 Minutes Motor Timeout = 60 Minutes
Green LED Idle State
Scanner Button Options
Scanner Button Options
Power-up Beep Control
POWER-UP Beep = ONE Beep POWER-UP Beep = Three Beeps
Good Read Beep Control
Good Read Beep Frequency
Good Read Beep Frequency
Good Read Beep Length
Good Read Beep Volume
Good Read Beep Volume = Medium LOW
Good Read Beep Volume
Good Read When to Indicate
RS-232 only
To set this feature Scan the Switch bar code
Use this feature to enable or disable scale operation
Scale Country Mode
Scale Country Mode = Australia
Scale Enforced Zero Return
Within 4 Minutes
Scale Interface Type
Scale Interface Type = RS-232 ICL
Scale Motion Level Filter
Scale Motion Level Filter
Scale LED Enable
Display
Remote Display Enable/Disable
Aux Port Mode
AUX Port Mode = External Handheld Input AUX Port Mode = PIR
Laser Failure Mode
Productivity Index Reporting PIR/Cashier Training CT
EAS Mode
EAS Features
EAS Mode = Disable EAS Mode = Coupled Mode
EAS Mode = Decoupled Mode EAS Mode = Hybrid Mode
EAS Beep Duration
To set the EAS Beep Duration Scan the Switch bar code
EAS Retry Count
Manual EAS Deactivation Push Button
Manual EAS Deactivation Push Button
Enabled
EAS Deactivation Duration Coupled
EAS Deactivation Duration Retry
EAS Deactivation Duration Manual
Interface Type
Interface Related Features
Specifies the current scanner interface. Selections are
IBM Port
Connect new interface cables
To select the desired interface
RS-232 Interface Selection
RS-232 Wincor-Nixdorf Interface Selection
RS-232 Single Cable Interface Selection
IBM Port 17 Interface Selection
IBM USB Interface Selection
Maximum Host-Transmitted Message Length
Number of Host Transmission Buffers
To specify no Global Prefix, scan
Global Prefix
SET Global Prefix Terminate Sequence
Global Suffix
Global Suffix = CR Global Suffix = CR LF
IBM Interface Options
IBM Features
IBM Scale Address
IBM Scale Address = 6B IBM Scale Address = 6E
IBM Transmit Labels in Code 39 Format
IBM USB Interface Options
Port
IBM USB Scanner Device Type
RS-232 Baud Rate
RS-232 Features
RS-232 Baud Rate
RS-232 Baud Rate
RS-232 Baud Rate
RS-232 Number of Data Bits
RS-232 Number of Stop Bits
RS-232 Parity = None RS-232 Parity = Even
RS-232 Parity
RS-232 Parity = Even RS-232 Parity = ODD
RS-232 Hardware Control
RS-232 Hardware Control
RS-232 Intercharacter Delay
RS-232 Software Flow Control
RS-232 Host Echo
RS-232 Host Echo Quiet Interval
RS-232 Ignore Host Commands
RS-232 TTL
RS-232 TTL Invert
RS-232 Beep on Ascii BEL
RS-232 Beep After Weigh
RS-232 Beep on Not on File
RS-232 ACK NAK Enable
100
RS-232 ACK Character
To specify the RS-232 ACK Character Scan the Switch bar code
102
RS-232 NAK Character
RS-232 Retry on ACK NAK Timeout
104
RS-232 ACK NAK Timeout Value
RS-232 ACK NAK Retry Count
106
RS-232 ACK NAK Error Handling
107
108
RS-232 Label ID Control
109
110
Single Cable RS-232 Options
Single Cable RS-232 Scanner Only Protocol
112
Single Cable RS-232 RTS CTS Selection
113
114
Single Cable RS-232 Use BCC
116
Single Cable RS-232 Use ACK/NAK
Single Cable RS-232 Use STX
118
Set Single Cable RS-232 STX Character
Single Cable RS-232 Use ETX
120
Set Single Cable RS-232 ETX Character
UPC-A Enable
Symbology Programming
122
UPC-A Number System Character Transmission
UPC-A Check Character Transmission
Enables/disables transmission of a UPC-A check character
124
Expand UPC-A to EAN-13
UPC/EAN AIM ID
126
UPC-A Label ID
UPC-A 2-Digit Supplemental Label ID
128
UPC-A 5-Digit Supplemental Label ID
UPC-A 128 Supplemental Label ID
130
UPC-E Enable
UPC-E Number System Character Transmission
UPC-E Check Character Transmission
Enables/disables transmission of a UPC-E check character
132
Expand UPC-E to UPC-A
134
Expand UPC-E to EAN-13
UPC-E Label ID
136
UPC-E 2-Digit Supplemental Label ID
UPC-E 5-Digit Supplemental Label ID
138
UPC-E 128 Supplemental Label ID
EAN-13 Enable
EAN-13 First Character Transmission
Enables/disables transmission of EAN/JAN-13 first character
140
EAN-13 Check Character Transmission
142
EAN-13 Isbn Conversion Enable
EAN 13 Label ID
144
EAN-13 2-Digit Supplemental Label ID
EAN-13 5-Digit Supplemental Label ID
146
EAN-13 128 Supplemental Label ID
Bookland AIM ID
148
Bookland Label ID
EAN-8 Enable
150
EAN-8 Check Character Transmission
Expand EAN-8 to EAN-13
152
EAN 8 Label ID
EAN-8 2-Digit Supplemental Label ID
154
EAN-8 5-Digit Supplemental Label ID
EAN-8 128 Supplemental Label ID
156
EAN-8 Decoding Levels
157
158
Other UPC/EAN Options
160
UPC/EAN Reconstruction
Price Weight Check = Disable
Price Weight Check
162
163
164
Enable EAN Two Label
Addons
166
UPC-A and EAN-13 Decoding Levels
168
169
170
Gtin Enable
Gtin Label ID
172
Gtin 2-Digit Supplemental Label ID
Gtin 5-Digit Supplemental Label ID
174
Gtin Code 128 Supplemental Label ID
RSS-14 Enable
176
RSS-14 Check Character Transmission
RSS-14/EAN-128 Emulation
178
RSS-14 2D Component Enable
RSS-14 AIM ID
180
RSS-14 Label ID
RSS Expanded Enable
182
RSS Expanded EAN-128 Emulation
RSS Expanded 2D Component Enable
184
RSS Expanded AIM ID
RSS Expanded Label ID
186
RSS Expanded Length Control
RSS Expanded Maximum Label Length
188
RSS Expanded Minimum Label Length
RSS Expanded Fixed Length
This feature specifies RSS Expanded first fixed length
190
This feature specifies RSS Expanded second fixed length
Code 39 Enable
192
Code 39 Start Stop Character Transmission
Character
Code 39 Check Character Calculation
194
Code 39 Check Character Transmission
Code 39 Full Ascii
196
Code 39 AIM ID
Code 39 Label ID
198
Code 39 Length Control
Code 39 Maximum Label Length
200
Code 39 Minimum Label Length
Code 39 Fixed Length
This feature specifies Code 39 first fixed length
202
This feature specifies Code 39 second fixed length
Code 39 Stitching
204
Pharmacode 39 Enable
Pharmacode 39 Start Stop Character Transmission
206
Pharmacode 39 Check Character Transmission
Pharmacode 39 Label ID
208
Code 128 Enable
Code 128 Transmit Function Characters
210
Convert Code 128 to Code
Code 128 AIM ID
212
Code 128 Label ID
Code 128 Fixed Length
Code 128 Length Control
214
Code 128 Maximum Label Length
Code 128 Minimum Label Length
Code 128 Fixed Length
This feature specifies Code 128 first fixed length
216
This feature specifies Code 128 second fixed length
218
Code 128 Stitching
EAN-128 Enable
220
EAN-128 AIM ID
EAN-128 Label ID
222
Interleaved 2 of 5 I 2 of 5 Enable
5 Check Character Calculation
224
5 Check Character Transmission
5 AIM ID
226
5 Label ID
5 Length Control
228
5 Maximum Label Length
5 Minimum Label Length
5 Fixed Length
This feature specifies I 2 of 5 first fixed length
230
This feature specifies I 2 of 5 second fixed length
232
5 Stitching
Codabar Enable
234
Codabar Start Stop Character Transmission
ABCD/TN* E ABCD/ABCD
Codabar Start Stop Character Set
236
Codabar Start Stop Character Match
238
Codabar Check Character Calculation
Codabar Check Character Transmission
240
Codabar AIM ID
Codabar Label ID
242
Codabar Length Control
Codabar Maximum Label Length
244
Codabar Minimum Label Length
Codabar Fixed Length
This feature specifies Codabar first fixed length
246
This feature specifies Codabar second fixed length
Codabar Stitching
248
Code 93 Enable
Code 93 AIM ID
250
Code 93 Label ID
Code 93 Fixed Length
Code 93 Length Control
252
Code 93 Maximum Label Length
Code 93 Minimum Label Length
Code 93 Fixed Length
This feature specifies Code 93 first fixed length
254
This feature specifies Code 93 second fixed length
256
Code 93 Stitching
MSI/Plessey Enable
258
MSI/Plessey Check Character Calculation
MSI/Plessey Number of Check Characters
260
MSI/Plessey Check Character Transmission
MSI/Plessey AIM ID
262
MSI/Plessey Label ID
MSI/Plessey Fixed Length
MSI/Plessey Length Control
264
MSI/Plessey Maximum Label Length
MSI/Plessey Minimum Label Length
MSI/Plessey Fixed Length
This feature specifies MSI/Plessey first fixed length
266
This feature specifies MSI/Plessey second fixed length
268
MSI/Plessey Stitching
Standard 2 of 5 Enable
270
Standard 2 of 5 Check Character Calculation
Standard 2 of 5 Check Character Transmission
272
Standard 2 of 5 AIM ID
Standard 2 of 5 Label ID
274
Standard 2 of 5 Length Control
Standard 2 of 5 Maximum Label Length
276
Standard 2 of 5 Minimum Label Length
Standard 2 of 5 Fixed Length
This feature specifies Standard 2 of 5 first fixed length
278
This feature specifies Standard 2 of 5 second fixed length
Standard 2 of 5 Stitching
280
Appendix a
LED and Beeper Indications
Controls and Indicators
Scanner and Scale LEDs
Mode
Deactivation status
Deactivator LED
Upon initiating this
Hybrid Mode
Volume/Tone Push Button
When the beeper Increments tone
Press Function Comment
Table A-4. Scale Zero Push Button Functions
Scale Zero Push Button
Calibration Switch Seal
Calibration Switch
Calibration Switch Cover
Wire Requirements
General Specifications
Introduction
RS-232 Cable Pinout
Connector Hardware
Scanner
RJ45, 10 Position
Cable Pinout Table B-2RS-232 Scale Cable Pinouts
Scale
Scanner and Scale
IBM Cable Pinout
Cable Pinout Table B-4IBM USB Cable Pinouts
IBM USB Cable Pinout
External Handheld Input
Auxilliary Port
Connector Hardware
Power Cable
Pin Molex
Pin SDL
Remote Display
EAS Deactivator Control Box Connection
EAS Comm Port
RJ10
Magellan
Appendix C Keypad
Magellan
Product Reference Guide
Magellan
Product Reference Guide
Magellan
Product Reference Guide
Magellan
Scanner responds to the following RS-232 commands
Accepting Commands from an RS-232 Scanner Host
Magellan
Appendix E Factory Defaults
Good Read When to
EAS Deactivation Duration Coupled
Ascii BEL
Enable
UPC/EAN AIM ID
UPC-E 128 Supple
RSS-14 AIM ID
RSS-14 Label ID
Code 39 Full Ascii
EAN-128 AIM ID
5 Maximum Label Length 5 Minimum 5 Fixed Length 5 Stitching
Codabar Fixed Length Codabar Stitching
MSI/Plessey Label ID
Standard 2 of 5 Mini Mum Label Length Standard 2 of 5 Fixed
Magellan
Handheld Data Format Requirements General
Appendix F Handheld Data Format Requirements
RSS-14
Datalogic Handheld Data Format Requirements
RSS Expanded
UPC-A with 2-Digit Supplemental
UPC-A with Code 128 Supplemental
UPC-A with 5-Digit Supplemental
UPC-E with 5-Digit Supplemental
UPC-E with 2-Digit Supplemental
UPC-E with Code 128 Supplemental
EAN-8 with 5-Digit Supplemental
EAN-8 with 2-Digit Supplemental
EAN-8 with Code 128 Supplemental
EAN-13 with 2-Digit Supplemental
EAN-13
EAN-13 with 5-Digit Supplemental
EAN-13 with Code 128 Supplemental
Code 39-Pharmacode
Code
Prefix must be an Ascii character Example
Check character must be included in label data
Codabar
Prefix must be an Ascii character %
Example #Code128.Test
Prefix must be an Ascii character @ Example @144769254
MSI/Plessey
Example E00060992011187
AIM Formats
Example E00000000998875
Digit Supplemental
Bookland
Code 128 Supplemental
Prefix must be Ascii characters M0 Example M0144769254
Prefix must be Ascii characters F0
RSS-14
Code 128 / EAN128
Magellan
Ascii Character Set
Italy
Top
Page
Image
Contents