Interleaved 2 of 5 (I 2 of 5) Enable
I 2 of 5 Fixed Length 2
This feature specifies I 2 of 5 second fixed length.
This applies when I 2 of 5 Length Control is set to
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
NOTE
To set this feature:
1.Scan the SWITCH bar code.
2.Scan the bar code, SET I 2 OF 5 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired fixed label length. The selectable range for this option is 00, or 02 to 50; even numbers only. Pad all single digit numbers with a leading zero to yield a
4.Complete the programming sequence by scanning the SWITCH bar code.
SET I 2 OF 5 FIXED LENGTH 2
Product Reference Guide |