A-8 Magellan® 9500

Manual EAS Deactivation Push Button

Using the programming bar codes contained in the Product Refer-

ence Guide (PRG) the button can be configured to operate always,

or only function when the scanner is enabled.

PRESS
DURATION FUNCTION COMMENT
MomentaryaManually initiates EAS
deactivation
Place the item with the EAS tag downstreamb of the
horizontal scan window and push the button.
3 Seconds upon
EAS error
Allows scanner to resume
function despite EAS sys-
tem failure (non-fatal
error)
EAS Failure Mode is indicatedc by:
- EAS LED blinks ON/OFF red, scanning disabled.
- FRU Status LED Indicator blinks ‘9’
- Error tone is sounded for one second
Upon pressing the button for 3 seconds, the scan-
ner will sound 3 high-pitched beeps, then resume
scan function. The EAS LED and FRU Status LED
will continue blinking as above, but at a slower rate
until EAS system function is restored.
a. For use in Coupled Mode only
b. “Downstream” in this case is defined as being the downstream side of the scan window from
the direction of product flow, or scanning direction.
c. If the EAS failure corrects itself, blinking will stop and the EAS LED will turn green.