Manual EAS Deactivation Push Button

Using the programming bar codes contained in the Product Refer- ence Guide (PRG) the button can be configured to operate always, or only function when the scanner is enabled.

PRESS

FUNCTION

COMMENT

DURATION

 

 

 

 

 

Momentarya

Manually initiates EAS

Place the item with the EAS tag downstreamb of the

deactivation

horizontal scan window and push the button.

 

 

 

 

 

 

EAS Failure Mode is indicatedc by:

 

 

- EAS LED blinks ON/OFF red, scanning disabled.

 

Allows scanner to resume

- FRU Status LED Indicator blinks ‘9’

 

- Error tone is sounded for one second

3 Seconds upon

function despite EAS sys-

Upon pressing the button for 3 seconds, the scan-

EAS error

tem failure (non-fatal

ner will sound 3 high-pitched beeps, then resume

 

error)

 

scan function. The EAS LED and FRU Status LED

 

 

 

 

will continue blinking as above, but at a slower rate

 

 

until EAS system function is restored.

 

 

 

a.For use in Coupled Mode only

b.“Downstream” in this case is defined as being the downstream side of the scan window from the direction of product flow, or scanning direction.

c.If the EAS failure corrects itself, blinking will stop and the EAS LED will turn green.