Motion Test
Product Reference Guide 5-3

Motion Test

This test verifies that the scale will not ‘zero’ when the weighing surface of
the scanner/scale is in motion.
1. Verify that the Yellow LED1 is on and the Remote Display reads
0.00 pounds or 0.000 kilograms.
2. Press lightly on the weigh platter of the scanner/scale with one hand
and at the same time press and release the Zero Push Button on the
operator’s panel. The Yellow LED should turn Off and the Remote
Display should not display 0.00 pounds or 0.000 kilograms.
3. Remove your hand from the weighing platform and verify that the
Yellow LED is On and the Remote Display reads 0.00 pounds or
0.000 kilograms.

Automatic Zero Setting Test

This test verifies that the scanner/scale automatic zero setting mechanism
is operating correctly.
1. Place 0.007 pounds (4 grams for metric) on the center of the weigh-
ing platform. The entire weight must be placed on the weighing
platform at once for this test to be valid. The Yellow LED should go
Off and the Remote Display should read 0.01 pounds (0.005 kilo-
grams).
1. Yellow LED indications can be configured via feature programming and may not be enabled for
certain functions.
NOTE
The scanner/scale has an adaptive zero capture mechanism that re-zeros the
scale over time if there is a slow change in the zero level; thus if all the weight
is not placed on the weighing surface at one time, the Yellow LED will remain
On and the Remote Display will read 0.00 pounds (0.000 kilograms). When the
weight is removed, the Yellow LED will turn off and the display will show a
minus sign . Press the Zero Push Button to re-zero the scale.
. lb