Motion Test
Motion Test
This test verifies that the scale will not ‘zero’ when the weighing surface of the scanner/scale is in motion.
1.Verify that the Yellow LED1 is on and the Remote Display reads 0.00 pounds or 0.000 kilograms.
2.Press lightly on the weigh platter of the scanner/scale with one hand and at the same time press and release the Zero Push Button on the operator’s panel. The Yellow LED should turn Off and the Remote Display should not display 0.00 pounds or 0.000 kilograms.
3.Remove your hand from the weighing platform and verify that the Yellow LED is On and the Remote Display reads 0.00 pounds or 0.000 kilograms.
Automatic Zero Setting Test
This test verifies that the scanner/scale automatic zero setting mechanism is operating correctly.
1.Place 0.007 pounds (4 grams for metric) on the center of the weigh- ing platform. The entire weight must be placed on the weighing platform at once for this test to be valid. The Yellow LED should go Off and the Remote Display should read 0.01 pounds (0.005 kilo- grams).
| The scanner/scale has an adaptive zero capture mechanism that |
| scale over time if there is a slow change in the zero level; thus if all the weight |
| is not placed on the weighing surface at one time, the Yellow LED will remain |
| On and the Remote Display will read 0.00 pounds (0.000 kilograms). When the |
NOTE | weight is removed, the Yellow LED will turn off and the display will show a |
minus sign | . | lb | . Press the Zero Push Button to |
1.Yellow LED indications can be configured via feature programming and may not be enabled for certain functions.
Product Reference Guide |