RS-232 Features

RS-232 Intercharacter Delay

Specifies delay between the end of one character and the beginning of the next in 10-millisecond increments.

To set the RS-232 Intercharacter Delay:

1.Scan the SWITCH bar code.

2.Scan the bar code below, SET RS-232 INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired delay. The selectable range is 0-100, which is the delay in 10-millisecond increments. Pad all single and double digit numbers with leading zeroes to yield a three-digit entry (000-100). Examples:

001 = 10ms

005 = 50ms

040 = 400ms

100 = 1,000ms (1 second)

4.The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned.

SET RS-232 INTERCHARACTER DELAY

Product Reference Guide

6-89

Page 205
Image 205