6.Power-up the scanner or scanner/scale by connecting the power cord to an AC power outlet. Wait for the unit to complete the Self test routine (10 seconds maximum). Successful scanner power-up is sig- nified by any or all of the following:

-Facet wheel shows movement

-Lasers turn on

-Status LED(s) turn on

-Speaker sounds tone(s)

-Remote display shows message

-A single red dot is visible on the 7-segment display

7.Power-up the POS terminal. Verify that scanning, deactivation and weighing functions are operational and that data is properly com- municated between the scanner and your POS system. (Scan, deac- tivate and weigh a few items.) If problems are encountered, refer to

Chapter 4, Problem Isolation.

8.You have now completed installation and system integration of the scanner or scanner/scale. At this point, the scale must be calibrated and certified in accordance with the requirements of your state and/ or local requirements. Refer to Chapter 5, Calibration, for calibra- tion procedures.