Swapping Position: EAS Single-Antenna ONLY

The EAS Antenna must be located in the position needed for your instal- lation. Reference Figure 2-18and. Locate it as described below:

1.Remove the platter (see Figure 2-22).

2.If the unit is a model containing a scale, and the scale assembly is determined to be in the position the EAS Single-Antenna should be with regard to product flow, proceed to the next step. Otherwise, skip to step 7.

3.Remove the screws that fasten the Load Cell/Spider Assembly to the scanner (see Figure 2-18) and carefully lift the entire assembly from the scanner cavity. Retain the screws for re-installation.

Figure 2-18. Locating the EAS Single-Antenna (Right-to-Left)

 

EAS Antenna

 

Product Flow

 

Load Cell/Spider

 

Assembly

 

Load Cell Harness