6-40 Magellan® 9500

Scale Motion Level Filter

In environments where checkstands generate excessive vibration, the scale
can be set to filter a certain amount of the motion with regard to its oper-
ation.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan. The strategy is
to select the lowest possible filter level needed that allows normal
scale operation.
3. Complete the programming sequence by scanning the SWITCH
bar code.
SCALE MOTION LEVEL FILTER = LOW
SCALE MOTION LEVEL FILTER = MEDIUM LOW
NOTE
This filter is generally used only in applications where scale error E_1 (too
much motion at power-up) has occurred.