MSI/Plessey Enable
Product Reference Guide 6-265

MSI/Plessey Minimum Label Length

This feature specifies the minimum allowable length of an MSI/Plessey
label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET MSI/PLESSEY MINIMUM LABEL
LENGTH below. You’ll need to cover any unused bar codes on this
and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired minimum label length. The selectable range for
this option is 4 to 16. Pad all single digit numbers with a leading
zero to yield a two-digit entry (04-16).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET MSI/PLESSEY MINIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters, but does not include
start, stop or full ASCII shift characters. This applies when MSI/Plessey
Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.