MSI/Plessey Enable

MSI/Plessey Minimum Label Length

This feature specifies the minimum allowable length of an MSI/Plessey label.

Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/Plessey Length Control is set to variable-length decoding.

NOTE

Minimum label length should be less than or equal to maximum label length.

To set this feature:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET MSI/PLESSEY MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that rep- resent the desired minimum label length. The selectable range for this option is 4 to 16. Pad all single digit numbers with a leading zero to yield a two-digit entry (04-16).

4.Complete the programming sequence by scanning the SWITCH bar code.

SET MSI/PLESSEY MINIMUM LABEL LENGTH

Product Reference Guide

6-265

Page 381
Image 381
Datalogic Scanning 9500, 9504 manual MSI/Plessey Minimum Label Length