EAS Features

Manual EAS Deactivation Push Button

NOTE

NOTE

This feature is for use in Coupled Mode1. When it is enabled, EAS deacti- vation can be manually initiated by placing the item with the EAS tag downstream2 of the horizontal scan window and pushing the Manual EAS Deactivation Push Button.

The scanner emits a clicking sound while in deactivation state.

Duration of deactivation state is determined by the feature, EAS Deactivation Duration — Manual.

Options are:

DISABLE — Manual EAS Deactivation Push Button disabled.

ENABLE ALWAYS —The Manual EAS Deactivation Push Button is always enabled.

ENABLE ONLY WHEN SCANNER ENABLED — The Manual EAS Deactivation Push Button is only available when the scanner is enabled and running.

Statistics are collected each time the Manual EAS Deactivation Push Button is used to deactivate an EAS tag.

1.See “EAS Mode” on page 48. for more information about Coupled Mode.

2.“Downstream” in this case is defined as being the downstream side of the scan window from the direction of product flow, or scanning direction.