![](/images/new-backgrounds/1122644/122644887x1.webp)
Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typi- cally observed in factory configurations of Datalogic handheld scanners.
RSS-14
•Prefix must be ASCII characters ‘R4’
•Check character must be included in label
•Application identifier “01” must follow the prefix and preceed the base label
•Label length excluding prefix characters must be 16 characters.
•Example: ‘R40101044123456789’
RSS Expanded
•Prefix must be ASCII characters ‘R4’
•Check character must be included in label
UPC-A
•Number system must be included in label data.
•Check digit must be included in label data and is assumed to be cor- rect.
•Prefix must be an ASCII character 'A' - total length including prefix must be 13.
•Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
•Number system must be included in label data.
•Check digit must be included in label data and is assumed to be cor- rect.
•Supplemental data is appended to base label.
•Prefix must be an ASCII character 'A' - total length including prefix must be 15.
•Example: 'A06099201118712'.
Magellan® 9500 |