8086 or 8088 CPU Package:
Accessories Required: HP 10305B Preprocessor
HP 10269C General Purpose Probe Interface
Maximum Clock Speed: 10 MHz clock input (at CLK)
Signal Line Loading: Maximum of two 74ALS TTL loads + 40 pF on any line
Microprocessor Cycles Identified: Memory read/write I/O read/write Code fetch Interrupt acknowledge Halt acknowledge Transfer to 8087 or 8089
Additional Capabilities: The 8086 or 8088 can be operating in Minimum or Maximum modes. The logic analyzer can capture all bus cycles (including prefetches) or can capture only executed instructions. To capture only executed instructions, the 8086 the 8086 or 8088 must be operating in the Maximum Mode.
Maximum Power Required: 1.0 A at + 5 Vdc, supplied by the logic
analyzer
Number of Probes Used: Three
Microprocessor Specific Measurements | HP 16510B |
14 - 6 |
|