Markers Statistics

Markers States

The Time X to O field will change according to the position of the X and O markers. It displays the total time between the states marked by the X and O markers.

When statistics are specified for markers, the logic analyzer will display the:

Total runs

Number of valid runs (runs where markers were able to be placed on specified patterns)

Minimum time between the X and O markers

Maximum time between the X and O markers

Average time between the X and O markers

How the statistics will be updated depends on the state trace mode (single or repetitive).

In repetitive, statistics will be updated each time a valid run occurs until you touch Stop. When you touch Run after Stop, the statistics will be cleared and will restart from zero.

In single, each time you touch Run an additional valid run will be added to the data and the statistics will be updated. This will continue unless you change the placement of the X and O markers between runs.

When the Count is set to State in the State Trace Specification menu, you have the option of placing the X and O markers on states of interest in the listing and the logic analyzer will tell you:

Trig(ger) to X

Trig(ger) to O

X to O (x)

This feature is similar to "Markers Time" except the number of states are displayed instead of time.

HP 16510B

Interpreting the Display

Front-Panel Reference

6 - 15