Setting the

Your timing measurement requires the timing analyzer to display the

Timing Analyzer

timing waveforms present on the buses when the routine is running. Since

you triggered the state analyzer on address 8930, you want to trigger the

Trigger

timing analyzer so the timing waveforms can be time correlated with the

 

state listing.

 

To set up the logic analyzer so that the state analyzer triggers the timing

 

analyzer, perform these steps:

 

1.

Display the Timing Trace Specification menu (Trace 2).

 

2.

Touch the field labeled Armed by Run.

 

3.

In the pop-up, touch the field labeled 68000STATE.

 

Your timing Trace specification should match the menu shown:

State Analyzer Arms

Timing Analyzer

Figure 12-8. Armed by 68000STATE

Using the Timing/State Analyzer

HP 16510B

12-10

Front-Panel Reference

Page 214